Emergency Responder Radio Coverage Systems (ERRCS / DAS) in Los Angeles

Ensure reliable first-responder radio communication inside your building — installed and tested according to LAFD, LADBS, NFPA, and California Fire Code requirements.

At Volta Electrical & Fire, we design, install, test, and maintain Emergency Responder Radio Coverage Systems (ERRCS), also known as DAS (Distributed Antenna Systems) with BDA (Bi-Directional Amplifiers), to ensure firefighters and law enforcement have uninterrupted radio communication during emergencies.

ERRCS/DAS is a lifesaving public-safety system that strengthens first-responder radio signals inside your building. Many structures block radio signals due to:

  • Concrete walls
  • Underground levels
  • Elevator shafts
  • Thick structural steel
  • Energy-efficient Low-E glass

An ERRCS system ensures critical emergency radio communication works anywhere inside the building, especially in areas where lives depend on fast coordination.

Building may be required to install or upgrade ERRCS if it meets any of the following:

  • There are more than 3-stories above grade plane.
  • The total building area is 50,000 square feet or more.
  • The total basement area is 10,000 square feet or more
  • Any basement or level that extends 2 or more stories below grade plane.

Los Angeles uses specific requirements from LAFDLADBSNFPA 72, and NFPA 1225/2019 for ERRCS compliance.

Signal Testing & RF Surveys

We conduct professional signal testing to measure:

  • LAFD radio channel strength (UHF, VHF, 700/800 MHz—depending on jurisdiction)
  • Dead zones inside the building
  • Signal penetration through walls and floors

System Design (RF Engineering)

Our design includes:

  • Donor antenna selection & placement
  • BDA / amplifier power levels
  • Coaxial and fiber pathway planning
  • Distributed antenna layout per floor
  • Heatmaps and RF modeling
  • Redundancy and survivability compliance with code

Installation & Commissioning

We install:

  • BDAs (Bi-Directional Amplifiers)
  • Coaxial and hybrid cables
  • Directional donor antennas
  • Distributed indoor antennas
  • Grounding, surge protection & monitoring

Annual Testing & Maintenance

We perform annual ERRCS testing as required by LAFD and California Fire Code, including:

  • Signal strength validation
  • Alarm monitoring verification
  • Battery & backup power tests
  • Cable and equipment inspection

We ensure full compliance with all Los Angeles and California requirements:

  • NFPA 1221 / NFPA 1225 (ERRCS installation & testing)
  • NFPA 72 (Monitoring and reporting)
  • California Fire Code – Section 510
  • LAFD Radio Communication Division Requirements
  • LADBS Plan Check Requirements
  • Title 19 Annual Testing

We handle plan submittalcoordination with inspectors, and final LAFD sign-off.

We perform RF testing inside your building to detect weak or no-coverage zones.

We create a full ERRCS/DAS design package:

  • Floorplans
  • Antenna layouts
  • Heatmaps
  • Riser diagrams
  • Equipment selection

Our licensed technicians install the full system, tested and certified.

We assist during inspection until the system passes all LAFD/LADBS requirements.

  • Licensed C-10 Electrical Contractor
  • LAFD Regulation 4 Certified Tester
  • Specialized in fire alarm, DAS, two-way communication, and life-safety systems
  • Experience with Los Angeles codes & inspectors
  • Fast turnaround on design, installation, and approval
  • Professional, clean installation
  • Family-owned, reliable service

Whether you need testing, repaires, upgrades, or a full ERRCS/DAS installation, we can help you meet LAFD requirements and keep your building 100% compliant.