Fire Sprinkler System
Fire Sprinkler Installation & Service in Los Angeles
Protecting life and property starts with a reliable fire sprinkler system. At Volta Electrical & Fire, Inc., we provide professional fire sprinkler installation, upgrades, repairs, and maintenance for residential, commercial, and multifamily buildings throughout Los Angeles.
Our services are fully compliant with NFPA 13, NFPA 25, the California Fire Code, and LAFD requirements, ensuring your building remains protected and inspection-ready year-round.
Our Fire Sprinkler Services
Fire Sprinkler Installation (New Construction & TI Projects)
We design and install complete sprinkler systems for new construction, tenant improvements, and renovation projects.
- NFPA 13, 13R, and 13D compliant systems
- Wet pipe, dry pipe, pre-action, and deluge systems
- Hydraulic calculations & layout coordination
- Collaboration with GCs, architects, and fire departments
Fire Sprinkler Upgrades & Retrofits
Older buildings may require upgrades to meet current code requirements or to correct system deficiencies. We handle:
- Adding or relocating heads
- Seismic bracing upgrades
- Pipe replacement
- System expansions
Sprinkler System Repairs
Fast, reliable repair service for all system types:
- Leaks and damaged piping
- Corroded or painted heads
- Faulty valves
- Mechanical and hydro issues
Fire Sprinkler Testing & Maintenance (NFPA 25)
Regular inspections are required by NFPA 25. We provide:
- Monthly/Quarterly/Annual inspections
- 5-year inspections & certifications
- Flow tests, valve checks, and gauge replacements
- LAFD & AHJ compliance reports
Fire Sprinkler Types We Install
Wet Pipe Systems
The most common system—faster response, lower maintenance, ideal for most commercial and residential buildings.
Dry Pipe Systems
Used in garages, parking structures, and areas exposed to freezing temperatures.
Pre-Action Systems
Designed for high-value rooms like data centers, electrical rooms, and communications spaces.
Deluge Systems
Required in high-hazard industrial applications.
Buildings in Los Angeles That Require Fire Sprinklers
In Los Angeles, buildings may require fire sprinkler systems if they fall under one or more of the following:
- Residential buildings with three or more dwelling units
- Buildings over 5,000 sq ft
- Buildings with occupancy classifications A, E, I, R
- Buildings with underground parking
- Any building where required by LAFD or LADBS due to fire flow or hazard assessment
Code & Compliance Requirements We Handle
We ensure your system meets:
- NFPA 13 / 13R / 13D
- NFPA 25 testing & maintenance
- California Fire Code (CFC)
- Los Angeles Fire Code & LAFD requirements
- LADBS plan check & approvals
- Seismic bracing and California amendments
- Hydraulic calculations and zone signage
Why Choose Us for Fire Sprinkler Installation?
- Work completed on schedule, with full documentation
- Licensed C-10 & full-service fire protection contractor
- LAFD-approved & compliant installations
- Unified services: fire alarm, DAS/ERRCS, two-way communication, annual testing
- Transparent pricing
- Coordination with inspectors to help you pass inspections the first time